07 Sep 2026
Oil and gas piping supply begins with a question about duty, not price: what the pipe has to carry, at what pressure and temperature, and whether it sits downhole, in a boiler house, on a rack or buried under a road. Once that is settled, the standard, the grade, the wall thickness and the coating follow almost automatically. This guide shows how to narrow six very different pipe families down to the line item that belongs on the purchase order.
IB Group supplies pipes for the oil, gas, energy and chemical sectors manufactured in compliance with the API 5L, EN and GOST standard systems, for onshore and offshore work alike. The full range sits on the oil-gas and industrial pipelines page; what follows is the reasoning behind choosing from it.
Buyers who start from a diameter usually end up re-specifying. Start from what the pipe does: these four duty classes barely overlap in metallurgy.
The table sets out the six families IB Group supplies, by EN and international specification. GOST equivalents are treated separately below, being a parallel system rather than a translation.
| Pipe family | Standards | Diameter | Wall thickness | Materials | Typical duty |
|---|---|---|---|---|---|
| High-pressure boiler pipes | EN 10216, ASTM A335 | Ø10–530 mm | 2–80 mm | 15CrMoG, 12Cr1MoVG, P91 | Power plants, steam systems, petrochemicals; to 620 °C |
| Casing and tubing (OCTG) | API 5CT, ISO 11960 | Ø10–406 mm | 5–25 mm | J55, K55, N80, P110 | Oil and gas wells, deep drilling, borehole protection |
| Seamless steel pipes | EN 10216, EN 10297 | Ø6–711 mm | 1–40 mm | P235GH, P265GH, 15Mo3 | High-pressure gas and water lines, petrochemicals, heat pipes |
| Anti-corrosion coated pipes | EN ISO 21809-1, EN 10289 | Ø20–1200 mm | 3-layer PE or FBE coating | Carbon steel with applied coating | Water and gas lines, marine infrastructure, chemicals; to 150 bar |
| Coated and insulated pipes | EN 253, EN 10217 | Ø20–1600 mm | 3–20 mm | Polyurethane foam, PE or PP jacket | Buried and marine lines, oil and gas transfer, heating systems |
| Special purpose pipes | EN 10255, EN 10296 | Ø10–1200 mm | 1–30 mm | 316L, 321, Inconel 625 | Aggressive chemical media, high-temperature and specialised service |
A seamless pipe is pierced and rolled from a solid billet, so it has no longitudinal weld and no heat-affected zone along its length. That removes the most common initiation site for cracking under cyclic pressure, which is why seamless product dominates high-pressure, high-temperature and sour service — and why its diameter range tops out sooner. IB Group's seamless line runs to Ø711 mm under EN 10216 and EN 10297, and to Ø720 mm under GOST 8731-74 and GOST 8732-78.
Welded pipe is the economical answer above that size and is sound for transport duty with a non-aggressive medium at moderate pressure. The insulated family shows the trade-off: the EN 253 carrier pipe is a welded pressure pipe to EN 10217, which is what makes the Ø1600 mm end of that range possible. For steel pipe in large-diameter networks the seam is rarely the limiting factor — the coating usually is.
Grade selection is where most re-orders originate:
Handling and inspection equipment is specified alongside the pipe; cranes and inspection machines sit on the machinery and equipment page.
Once a pipe goes underground, its service life is governed by what is on the outside. Anti-corrosion coated pipes to EN ISO 21809-1 and EN 10289 carry a three-layer polyethylene or fusion-bonded epoxy coating, are supplied from Ø20 to Ø1200 mm, and are rated for −30 to +100 °C at up to 150 bar; the GOST epoxy and polyurethane equivalents run Ø25–1000 mm, −40 to +120 °C and up to 180 bar — a wider temperature band that matters in continental climates.
Coated and insulated pipes to EN 253 are a different product: polyurethane foam is injected between an inner carrier pipe and an outer casing under a polyethylene or polypropylene jacket, giving thermal performance as well as corrosion protection across Ø20–1600 mm. These are the pipes used for district heating, buried construction and marine water and gas pipe runs. Whichever is chosen, budget for field joints: factory coating stops short of the ends, and site-made joints are where buried lines fail first.
Projects in Azerbaijan and the wider CIS routinely mix all three. A refinery upgrade may run new EN-specified process lines into a plant whose network was built to GOST, while the wells feeding it are on API product. None is "better"; they differ in how chemistry is expressed, how testing is defined and how tolerances are written, which is why grade equivalence is always approximate. Specify one system per line, and state the interface points explicitly.
That interface work is contractual as much as technical: the wording of the technical annexes decides who carries the risk of a mismatch, which is why contract support services and project management sit alongside supply rather than after it. IB Group's work on pipeline and valve supply for the Heydar Aliyev Oil Refinery and on the Azərkimya pipeline renewal are examples of supply into existing industrial networks.
A quotation is only as good as the enquiry behind it. A complete request states:
Valves are specified against the same duty data, so sending the pipe and oil-gas and industrial valves requirements together saves a round trip. Pricing and delivery are confirmed per order at the quotation stage — send the parameters above through the contact page and the technical team will respond with a specification and an offer.
A seamless pipe is formed from a solid billet and has no longitudinal weld; a welded pipe is formed from plate or strip and joined along its length. Removing the seam removes a common crack initiation site, which is why seamless product is preferred for high pressure, high temperature and sour service, while welded pipe is more economical at large diameters. IB Group's seamless range covers Ø6–711 mm to EN 10216 and EN 10297; welded carrier pipe to EN 10217 underpins the insulated range to Ø1600 mm.
All three are supplied and all three are valid; the choice follows the existing network and the project specification rather than technical superiority. If the line ties into a plant built to GOST, staying within GOST simplifies spares, welding procedures and inspection, while new-build process and transmission lines are commonly specified to EN or API 5L. Specify one system per line and define the interface points, because grade equivalences are approximate.
A buried line needs external protection engineered as part of the product. Anti-corrosion coated pipes to EN ISO 21809-1 and EN 10289, with three-layer polyethylene or fusion-bonded epoxy coating, are supplied from Ø20 to Ø1200 mm for −30 to +100 °C at up to 150 bar; GOST epoxy and polyurethane equivalents are rated −40 to +120 °C and up to 180 bar. If thermal performance is also needed, EN 253 insulated pipes cover Ø20–1600 mm, and field joint protection belongs in the scope.
High-pressure boiler pipes are the family designed for it. Supplied to EN 10216 and ASTM A335 in Ø10–530 mm with walls from 2 to 80 mm, they use creep-resistant grades 15CrMoG, 12Cr1MoVG and P91 and are rated to a maximum of 620 °C. The GOST equivalent, in grades 20, 12X1MΦ and 12X2MΦ, covers Ø16–426 mm with walls of 2–36 mm and a maximum of 560 °C. That temperature difference is usually the deciding factor when uprating an existing boiler house.
State the medium and whether the service is sour, the design pressure and temperature, the outside diameter and wall thickness or the pressure class to size against, the standard system and grade, the end finish and connector type, any coating or insulation requirement including field joints, and the quantity, delivery point and documentation package expected on delivery. The technical team can then specify from the pipe range; price and delivery schedule are confirmed per order at the quotation stage.

13 Sep 2026
What API 5CT actually covers, why threads sit in API 5B, where API 5L begins, how J55 to P110 grades read, how LTC, BTC, EUE and premium connectors differ, and what to require on delivery.

10 Sep 2026
What a fish plate in railway track does, how the double-headed section clamps a rail joint, 1R65 and 2R65 sizes and weights, EN versus GOST steel grades, and how to match a plate to your rail profile.

07 Sep 2026
Which valve family fits which duty, how pressure and temperature decide between carbon and stainless steel bodies, what API 6D, EN 12516, EN 593 and GOST 33259 govern, and the checklist to send with an enquiry.